{"created":"2023-06-20T15:53:19.190610+00:00","id":144,"links":{},"metadata":{"_buckets":{"deposit":"26717d96-f26b-453a-b517-5b0a05abceed"},"_deposit":{"created_by":2,"id":"144","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"144"},"status":"published"},"_oai":{"id":"oai:fukui-hsu.repo.nii.ac.jp:00000144","sets":["24:36"]},"author_link":["323","322"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-06-30","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"24","bibliographicPageStart":"21","bibliographicVolumeNumber":"3","bibliographic_titles":[{"bibliographic_title":"新田塚医療福祉センター雑誌"},{"bibliographic_title":"Journal of Nittazuka Medical Welfare Center","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"日々変動する検査データのなかで、血球算定のみに起こる原因不明の大きなデータ変動事例について原因追究とその検証を行うため、シリンジ内での時間経過と共に起こる変化を再現し検討した。結果、時間経過に伴い赤血球系で偽低値化し、MCV系は殆ど変動が認められず、白血球系で偽高値化を示し、その変動の程度に血沈亢進の程度が大きく影響していた。さらに、血沈正常の場合に限り3分以内であれば、偽低値・偽高値化は認められないことがわかった。正確なデータ報告には先ず正しい採血、つまりこの場合はより速やかな分注作業が絶対であると言っても過言ではない。","subitem_description_type":"Abstract"}]},"item_10001_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.57502/00000132","subitem_identifier_reg_type":"JaLC"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"福井医療大学"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13492519","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"天谷, 聡子"}],"nameIdentifiers":[{"nameIdentifier":"322","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山本, 智恵"}],"nameIdentifiers":[{"nameIdentifier":"323","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-12-15"}],"displaytype":"detail","filename":"2006-5.pdf","filesize":[{"value":"3.6 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"2006-5.pdf","url":"https://fukui-hsu.repo.nii.ac.jp/record/144/files/2006-5.pdf"},"version_id":"5d11ed4b-76f7-40f7-9b4d-b96f1c6889f3"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"自動血球計測時における偽低値・偽高値とその原因、及び検証","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"自動血球計測時における偽低値・偽高値とその原因、及び検証"}]},"item_type_id":"10001","owner":"2","path":["36"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-06-30"},"publish_date":"2006-06-30","publish_status":"0","recid":"144","relation_version_is_last":true,"title":["自動血球計測時における偽低値・偽高値とその原因、及び検証"],"weko_creator_id":"2","weko_shared_id":2},"updated":"2023-06-20T15:56:50.973102+00:00"}