{"created":"2023-06-20T15:53:22.712857+00:00","id":308,"links":{},"metadata":{"_buckets":{"deposit":"84bba179-92f7-4544-9682-5d21c6bf448c"},"_deposit":{"created_by":2,"id":"308","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"308"},"status":"published"},"_oai":{"id":"oai:fukui-hsu.repo.nii.ac.jp:00000308","sets":["24:42"]},"author_link":["1085","1087","1031","1086"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-03-31","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"19","bibliographicPageStart":"15","bibliographicVolumeNumber":"8","bibliographic_titles":[{"bibliographic_title":"新田塚医療福祉センター雑誌"},{"bibliographic_title":"Journal of Nittazuka Medical Welfare Center","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"現在、当院で撮影されているデジタルマンモグラフィの画質や石灰化病変が、以前のアナログマンモグラフィと比較して、どのように変化したのか確認すべく、アナログ画像とデジタル画像の両方を撮影した同一患者のうちで、石灰化所見がある画像フィルムについて視覚評価を行った。さらに、微細石灰化症例に対して、従来処理に加え、強調度を変えた強調1、強調2の周波数処理を行い三者間で視覚評価し、アナログ画像との比較を行った。その結果、従来処理のデジタル画像は、アーチファクト、乳腺内コントラスト、乳腺外コントラスト、粒状性、鮮鋭度のすべてにおいてアナログ画像より優れていたが、石灰化識別能は存在診断、質的診断ともにアナログ画像より劣っていた。周波数処理タイプ別による石灰化識別能は従来処理<強調1<強調2の順に優位に優れ(p<0.01)、強調2処理を行うことにより従来処理でアナログ画像より劣っていた石灰化識別能が上昇に転じ、アナログ画像と同等の識別能が得られた。これにより、石灰化診断が必要な症例には今回の周波数処理強調2を追加することで、臨床診断にも役立てることができると考える。","subitem_description_type":"Abstract"}]},"item_10001_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.57502/00000296","subitem_identifier_reg_type":"JaLC"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"福井医療大学"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13492519","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"深田, 由香里"}],"nameIdentifiers":[{"nameIdentifier":"1031","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"虎尾, 政美"}],"nameIdentifiers":[{"nameIdentifier":"1085","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"土田, 千賀"}],"nameIdentifiers":[{"nameIdentifier":"1086","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩崎, 俊子"}],"nameIdentifiers":[{"nameIdentifier":"1087","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-12-20"}],"displaytype":"detail","filename":"BD00010055_001.pdf","filesize":[{"value":"5.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"BD00010055_001.pdf","url":"https://fukui-hsu.repo.nii.ac.jp/record/308/files/BD00010055_001.pdf"},"version_id":"3413c284-c555-4e56-8afe-76d5f16ad5ab"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"周波数処理によるCRシステム デジタルマンモグラフィの石灰化識別能の向上","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"周波数処理によるCRシステム デジタルマンモグラフィの石灰化識別能の向上"}]},"item_type_id":"10001","owner":"2","path":["42"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-03-31"},"publish_date":"2012-03-31","publish_status":"0","recid":"308","relation_version_is_last":true,"title":["周波数処理によるCRシステム デジタルマンモグラフィの石灰化識別能の向上"],"weko_creator_id":"2","weko_shared_id":2},"updated":"2023-06-20T15:57:53.102037+00:00"}