{"created":"2023-06-20T15:53:16.214214+00:00","id":81,"links":{},"metadata":{"_buckets":{"deposit":"9b1317e6-55b4-425f-aca1-7413857bf34c"},"_deposit":{"created_by":2,"id":"81","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"81"},"status":"published"},"_oai":{"id":"oai:fukui-hsu.repo.nii.ac.jp:00000081","sets":["6:18"]},"author_link":["125","124","123","126"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-09-30","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"15","bibliographicPageStart":"11","bibliographicVolumeNumber":"15","bibliographic_titles":[{"bibliographic_title":"福井医療科学雑誌"},{"bibliographic_title":"Fukui Journal of Medical Sciences","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"頭部Magnetic Resonance Venographyでの3D- Phase Contrast法における空間分解能及び時間分解能を改善することを目的として,撮像条件を検討した.本研究に同意を得られた健常人を対象に,velocity encoding・FlipAngle・スライス厚の検討を行い従来の撮像条件と新たに設定した撮像条件とでMRVを撮像し,静脈洞の描出能,画質及び撮像時間を比較検討した.その結果,従来の撮像条件に比べ新たな撮像条件では,最適な撮像条件を設定できたことで静脈洞の描出能及び画質は改善し,撮像時間も短縮された.また,静脈洞の描出能,画質の向上及び撮像時間の短縮によって,診断能の向上や被検者の負担軽減につながる.","subitem_description_type":"Abstract"}]},"item_10001_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.57502/00000069","subitem_identifier_reg_type":"JaLC"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"福井医療大学"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"24240176","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"柳内, 和也"}],"nameIdentifiers":[{"nameIdentifier":"123","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"加藤, 寛道"}],"nameIdentifiers":[{"nameIdentifier":"124","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"堀江, 慶一郎"}],"nameIdentifiers":[{"nameIdentifier":"125","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"土田, 千賀"}],"nameIdentifiers":[{"nameIdentifier":"126","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-12-14"}],"displaytype":"detail","filename":"2018093003.pdf","filesize":[{"value":"317.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"2018093003.pdf","url":"https://fukui-hsu.repo.nii.ac.jp/record/81/files/2018093003.pdf"},"version_id":"4556cf96-180e-4d4b-ab29-2f65708ef3fa"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"頭部MR静脈撮像検査(Magnetic Resonance Venography:MRV)の最適化","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"頭部MR静脈撮像検査(Magnetic Resonance Venography:MRV)の最適化"}]},"item_type_id":"10001","owner":"2","path":["18"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-01-28"},"publish_date":"2019-01-28","publish_status":"0","recid":"81","relation_version_is_last":true,"title":["頭部MR静脈撮像検査(Magnetic Resonance Venography:MRV)の最適化"],"weko_creator_id":"2","weko_shared_id":2},"updated":"2023-06-20T15:59:45.172563+00:00"}