WEKO3
アイテム
{"_buckets": {"deposit": "ec35cbf4-141f-4aba-8b66-c6a6852b8807"}, "_deposit": {"created_by": 2, "id": "337", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "337"}, "status": "published"}, "_oai": {"id": "oai:fukui-hsu.repo.nii.ac.jp:00000337", "sets": ["43"]}, "author_link": ["1135", "1134", "1137", "1133", "1136"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-12-01", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "79", "bibliographicPageStart": "77", "bibliographicVolumeNumber": "9", "bibliographic_titles": [{"bibliographic_title": "新田塚医療福祉センター雑誌"}, {"bibliographic_title": "Journal of Nittazuka Medical Welfare Center", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "当院術後深部静脈血栓症発生頻度および深部静脈血栓症スクリーニング検査法としてのDーダイマー値の有用性について検討した。当院で施行した人工股関節置換術9例、人工膝関節置換術18例について、術前と術後7日目にD-ダイマー値測定と下肢静脈エコーを行った。その結果、術後深部静脈血栓症発生頻度は人工股関節置換術0%、人工膝関節置換術33.3%であった。術後7日目のDーダイマー値については、血栓あり群は血栓なしの群より、有意に高値を示した。術後7日目のD-ダイマー値のカットオフ値を11μg/mlとすると感度、陰性予測値は100%となり、D-ダイマー値は深部静脈血栓症スクリーニング検査法として有用であると考える。", "subitem_description_type": "Abstract"}]}, "item_10001_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.57502/00000325", "subitem_identifier_reg_type": "JaLC"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "福井医療大学"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "13492519", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "飛田, 梨紗"}], "nameIdentifiers": [{"nameIdentifier": "1133", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加納, 幸代"}], "nameIdentifiers": [{"nameIdentifier": "1134", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高田木, 由実"}], "nameIdentifiers": [{"nameIdentifier": "1135", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "渡邉, 和則"}], "nameIdentifiers": [{"nameIdentifier": "1136", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "勝尾, 信一"}], "nameIdentifiers": [{"nameIdentifier": "1137", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2022-12-20"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "BD00012574_001.pdf", "filesize": [{"value": "2.6 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2600000.0, "url": {"label": "BD00012574_001.pdf", "url": "https://fukui-hsu.repo.nii.ac.jp/record/337/files/BD00012574_001.pdf"}, "version_id": "b95402f2-c60f-4c87-ac2d-aa0c5c93c1b9"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "人工股関節置換術・人工膝関節置換術における深部静脈血栓症のスクリーニング~Dーダイマー値と下肢静脈エコーとの比較検討~", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "人工股関節置換術・人工膝関節置換術における深部静脈血栓症のスクリーニング~Dーダイマー値と下肢静脈エコーとの比較検討~"}]}, "item_type_id": "10001", "owner": "2", "path": ["43"], "permalink_uri": "https://doi.org/10.57502/00000325", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-12-01"}, "publish_date": "2012-12-01", "publish_status": "0", "recid": "337", "relation": {}, "relation_version_is_last": true, "title": ["人工股関節置換術・人工膝関節置換術における深部静脈血栓症のスクリーニング~Dーダイマー値と下肢静脈エコーとの比較検討~"], "weko_shared_id": 2}
人工股関節置換術・人工膝関節置換術における深部静脈血栓症のスクリーニング~Dーダイマー値と下肢静脈エコーとの比較検討~
https://doi.org/10.57502/00000325
https://doi.org/10.57502/00000325b1aed023-e3e8-4388-bb48-18fc83d6113a
名前 / ファイル | ライセンス | アクション |
---|---|---|
BD00012574_001.pdf (2.6 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-12-01 | |||||
タイトル | ||||||
タイトル | 人工股関節置換術・人工膝関節置換術における深部静脈血栓症のスクリーニング~Dーダイマー値と下肢静脈エコーとの比較検討~ | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
ID登録 | ||||||
ID登録 | 10.57502/00000325 | |||||
ID登録タイプ | JaLC | |||||
著者 |
飛田, 梨紗
× 飛田, 梨紗× 加納, 幸代× 高田木, 由実× 渡邉, 和則× 勝尾, 信一 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 当院術後深部静脈血栓症発生頻度および深部静脈血栓症スクリーニング検査法としてのDーダイマー値の有用性について検討した。当院で施行した人工股関節置換術9例、人工膝関節置換術18例について、術前と術後7日目にD-ダイマー値測定と下肢静脈エコーを行った。その結果、術後深部静脈血栓症発生頻度は人工股関節置換術0%、人工膝関節置換術33.3%であった。術後7日目のDーダイマー値については、血栓あり群は血栓なしの群より、有意に高値を示した。術後7日目のD-ダイマー値のカットオフ値を11μg/mlとすると感度、陰性予測値は100%となり、D-ダイマー値は深部静脈血栓症スクリーニング検査法として有用であると考える。 | |||||
書誌情報 |
新田塚医療福祉センター雑誌 en : Journal of Nittazuka Medical Welfare Center 巻 9, p. 77-79, 発行日 2012-12-01 |
|||||
出版者 | ||||||
出版者 | 福井医療大学 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 13492519 |